English
  • LTH-wUV38xFeature&BenefitSpatial coupling technology, the peak wavelength is 375nm;Light weight, compact structure and easy maintenance;Long life, more than 10,000 hours;Output power 3W/5W/10W/20W;High stability during life.Source: Literonics

    323
    2
    1
  • What version of RDworks is supposed to be used with this. I have v8.01.66 and am unable to connect via static wired ethernet or wifi. I can ping both ip's so I know it's online, just no software control via RDworks or lightburn

    05-17
    371
    6
    0
  • Feature&BenefitThe absorption rate on the highly reflective metal is 3 to 20 times that of the infrared laser;There is no spatter in the process of welding Cu, Au and AL metals, which improves the welding quality;The combination of blue laser and infrared laser can greatly improve efficiency and reduce costs.Source: Literonics

    259
    0
    0
  • Handheld laser welding is another new application technology of laser. Its principle is to aim a highly energy dense laser beam at the material, thereby rapidly heating and melting the material locally, forming a welding interface, and ultimately achieving the welding effect. Handheld laser welding equipment mainly includes lasers, welding heads, c...

    2024-10-22
    398
    2
    0
  • I use a new Monport 80w camera with RDC6442G.However, I hit autofocus in Lightburn or the Z-axis menu and the camera breaks. (This camera does not have a Z-axis limit switch).Can I disable the autofocus feature in the control panel or machine settings?I looked at the Ruida manual but it didn't help much with this problem.

    338
    1
    1
  • The servo motor only moves in one direction,How should I handle it?

    05-20
    331
    1
    0
  • The 20W50uj infrared femtosecond laser adopts an all-fiber structure and an integrated sealed cavity, with stable performance and strong anti-interference ability. Narrow pulse widths and higher temporal quality are obtained with efficient dispersion management.Main features:User-friendly interfaceReal-time state monitoringHigh beam quality; Suit...

    05-10
    276
    1
    0
  • Fault analysis:1. The installation path is not selected correctly2. No VBA plugin downloaded3. The VBA plugin version is incorrect compared to the CAD version Solution:The reinstallation path is correct. After checking, it was found that the CAD version sent was 2023 and the VBA plugin version was 2018, which caused the failure. After re downlo...

    05-19
    248
    0
    0
  • Frequency converters are widely used in modern industry, but sometimes there are occasional trips that cause inconvenience to production. Below, we will analyze the common causes of frequency converter tripping and provide corresponding solutions.Overload causes trippingOverload is one of the common causes of frequency converter tripping. When th...

    01-14
    921
    1
    1
  • Fault analysis:1. No fan enabled2. Relay wiring is incorrect3. Layer setting issue Solution:The layer parameters are set to not blow air

    05-19
    222
    0
    0
  • Fault analysis:1. Layer output setting error2. The laser power setting is too small3. Wrong selection of the number of interchangeable heads Solution:Despite increasing the power, there is still no light, and the cutting action is normalUpon inspection, it was found that the number of interchangeable heads was set to 2, but in reality, there wa...

    05-19
    230
    0
    0
  • Fault analysis:1. Enable multiple positioning points2. Failed to locate successfully3. Panel button malfunction4. Return setting error Solution:Upon checking the user parameters, it was found that the return method has been changed to return to the mechanical origin. Simply change the return to the positioning point

    210
    0
    0
  • Fault analysis:1. Abnormal reset parameters2. Panel reset button malfunction3. Unstable and undervoltage power supply voltage4. Program firmware malfunction Solution:Firstly, check whether the reset parameters are normal, whether the user parameter reset is turned on, whether the motherboard wiring is under voltage, and confirm that the output ...

    05-19
    226
    0
    0
  • HelloDoes anyone knows, will LightBurn works with Ruida RDC8445S ?I try trial version, and Ruida always in disconnected state, Serial USB/Ethernet IP both not works.PS: RDWorks detect controller by USB and IP (WiFi) - both success 

    262
    1
    0
  • GZTECH QCW products, single-mode and multi-mode optional, suitable for precision welding and cutting applications of metals/ceramics and other materialsPower:75W 150W 300W 450W 600WOverviewGZTECH QCW lasers support simultaneous operation in both continuous and high peak power pulsed modes and can handle processing tasks that previously required ...

    05-15
    286
    0
    1