Maintenance personnel have technical experience, level of expertise, and familiarity with chiller equipment, which enables them to solve equipment failures more quickly and accurately. If the maintenance personnel handle the fault improperly, it will lead to increased costs and various impacts, and also leave hidden dangers for the next fault.1、 ...
2024-06-286010Application fields of water-cooled industrial chillers:1. Industrial productionWater cooled industrial chillers are widely used in the production process of industries such as chemical, plastic, pharmaceutical, food, and beverage. These industries have extremely strict requirements for temperature control. Water cooled industrial chillers, with th...
2024-06-266710At the beginning of the operation of the chiller, it is necessary to regularly pay attention to the oil level, return oil condition, and cleanliness of the chiller compressor. If the oil level drops, it should be added in a timely manner. If dirt is found in the oil, it should be replaced in a timely manner to prevent poor lubrication and affect th...
2024-06-256610I believe many friends will encounter such problems when using industrial chillers. The expansion valve is frosting! So why does it frost? How to solve this problem?Discussion and analysis1. Some people will first consider whether the expansion valve is blocked or opened too small.2. Some people may also consider whether the fan is faulty.3. Of co...
2024-06-244910When choosing a chiller, air cooling and water cooling each have their own advantages and applicability, and the specific choice depends on your specific needs and conditions. Here are some key points to help you make wiser decisions when making choices:1. Cooling method: The air-cooled chiller is cooled by air, while the water-cooled chiller is ...
2024-06-215000The frequency of water change for industrial chillers is mainly determined by the operating environment and water quality. In general:1. Change water every six months in a high-quality environment.In high-quality environments, such as laboratories or independent air-conditioned rooms, the circulating water of industrial chillers can be changed ev...
2024-06-195010Industrial chillers are widely used equipment in various industries, consisting of multiple components such as sheet metal cabinets, refrigerant circulation systems, water circulation systems, and electrical self-control systems. As the outer shell of the chiller, the sheet metal cabinet is made of high-strength sheet metal material, which is sturd...
2024-06-185200Do UV laser marking machines need to be equipped with laser chillers?
2024-06-135521Water chillers, especially those used in industrial manufacturing, usually have advantages such as intelligence, energy conservation, and wide applications. By understanding and mastering the normal operation signs and cooling capacity adjustment methods of the managed water chillers, it is the foundation for mastering the use of the unit. It is al...
2024-06-125710The summer heat is coming, and the chiller cannot avoid its impact. It is important to maintain and upkeep the chiller during the arrival of summer, which not only improves work efficiency but also avoids high temperature alarm faults caused by hot weather.Summer maintenance and upkeep methods:1. Due to the inevitable high temperatures in summer,...
2024-06-064810Industrial chillers, like humans, can also get sick. Firstly, we need to consider why the malfunction occurred and what caused it, so that we can take corresponding measures to prevent it and reduce the equipment failure rate based on the situation.To reduce the failure rate of chillers, the following aspects need to be done well1. Strengthen the...
2024-06-0452101. Increased compressor loadThere are many reasons for the increase in compressor load, but if industrial chillers lack fluorine, the compressor load will inevitably increase. If the air and water cooling systems do not have poor heat dissipation faults, the reason for the increase in compressor load is often due to insufficient fluorine.2. Cooli...
2024-06-0354101. Check for air in the chiller cooling system. When installing a chiller, there should be no air inside the unit, or the pump, or the pipeline, even a little air, and the chiller will not work normally. In addition, there is a film inside the pump, which must be torn off before installation. Otherwise, the water has no way to circulate or the circ...
2024-05-315910The industry where chillers are used is very extensive, especially in industrial manufacturing. Chillers also have energy-saving and intelligent features. Understanding the normal operation signs and cooling capacity adjustment methods of industrial chillers can enable better operation of chillers. At the same time, it is important to pay attention...
2024-05-283710As an important equipment in modern industrial production, the operational efficiency and stability of industrial chillers cannot be ignored in their impact on the production process. After all, these details not only affect the performance of industrial chiller equipment, but also directly affect production efficiency and the service life of the e...
2024-05-278310