Русский

Nanchang University research progresses in acoustic resolution photoacoustic microimaging enhancement

600
2024-09-18 11:30:16
Посмотреть перевод

As a promising imaging modality that combines the high spatial resolution of optical imaging and the deep tissue penetration ability of ultrasound imaging, photoacoustic microscopy (PAM) has attracted a lot of attention in the field of biomedical research, and has a wide range of applications in many fields, such as tumor detection, dermatology, and vascular morphology assessment. Depending on the imaging modality, PAM can be categorized into optical resolution photoacoustic microscopy (OR-PAM) and acoustic resolution photoacoustic microscopy (AR-PAM.) OR-PAM utilizes optically strong focusing to achieve high lateral resolution (<5 μm) imaging. However, light scattering within biological tissues limits the penetration depth of OR-PAM (no more than 1-2 mm). In contrast, AR-PAM exhibited deeper imaging (~3-10 mm). However, this enhanced effect is accompanied by a decrease in lateral resolution (>50 μm) and an increase in background noise. How to realize AR-PAM imaging with high lateral resolution without sacrificing imaging depth has been a pressing problem for PAM.

Recently, a research team from the Laboratory of Imaging and Visual Representation, Nanchang University, proposed an acoustic-resolution photoacoustic microscopy enhancement strategy based on the mean-reverting diffusion model to realize the transition from acoustic resolution to optical resolution. The result is published as “Mean-reverting diffusion model-enhanced acoustic-resolution photoacoustic microscopy for resolution enhancement: toward The results were published in the Journal of Innovative Optical Health Sciences, a leading journal in the field of biomedical photonics, under the title of “optical resolution”.

Main research content

The research team proposes a mean-regression diffusion model-based enhancement strategy for acoustic-resolution photoacoustic microscopy to achieve enhancement from acoustic to optical resolution. In the training stage, a mean-reversion diffusion model is trained to learn a priori information about the data distribution by modeling the quality reduction process from high-resolution PAM images to low-resolution AR-PAM images with fixed Gaussian noise. In the reconstruction stage, the learned a priori information is used to iteratively sample the noise states to generate a high resolution image from the low quality AR-PAM image. 

 


Figure 1.Flowchart of AR-PAM enhancement algorithm based on mean-reversion diffusion modeling


As a validation, the research team evaluated the performance of the proposed method using in vivo mouse experimental data. In a scene with a lateral resolution of 55 μm and a signal-to-noise ratio (SNR) of 35 dB, the method was compared with the conventional RL deconvolution method, the CycleGAN method, and the FDUnet method, and the results are shown in Figure 2. The enhancement results of the proposed method show higher quality and superior lateral resolution. The Peak Signal to Noise Ratio (PSNR) and Structural Similarity (SSIM) reached 31.96 dB, 0.91, respectively, which is 136% and 54% improvement over the RL deconvolution method. 

 



Fig. 2. Comparison of the reconstruction results of different methods.


In addition, in order to further validate the enhancement performance of the model on large-scale images, the research team also used complete live mouse cerebrovascular images for experiments. It can be seen that the enhanced image (as shown in Fig. 3(c)) has a clearer vascular topology, higher lateral resolution, and stronger image contrast. It is noteworthy that the continuity of the vessels at the sub-image joints is well maintained without obvious artifacts. Compared with the true-value image (as shown in Fig. 3(a)), the PSNR and SSIM of the AR-PAM image (as shown in Fig. 3(b)) were 19.39 dB and 0.53, respectively, and those of the model-enhanced image were improved to 24.72 dB and 0.73, respectively, which were 27% and 38% higher compared to the AR-PAM, respectively. The results show that the proposed method can still significantly improve the lateral resolution of large-size AR-PAM images. 

 



Fig.3. Resolution enhancement results for large size AR-PAM images.



Conclusion and Outlook

This study proposes a new AR-PAM enhancement strategy based on a mean-reversion diffusion model to achieve a balance between AR-PAM and OR-PAM imaging depth and lateral resolution. The method models the quality reduction process from OR-PAM to low quality AR-PAM images. Subsequently, a numerical method is used to iteratively perform an inverse-time SDE aimed at reconstructing high-quality images from a homogenized state. The method significantly improves the lateral resolution of AR-PAM without sacrificing the imaging depth, which has the potential to improve the quality of PAM imaging and extend its application range.

Source: opticsky

Связанные рекомендации
  • Super-resolution fluorescence microscopy utilizes fluorescent probes and specific excitation and emission programs

    Super-resolution fluorescence microscopy surpasses the diffraction limit of what used to be a barrier by using fluorescent probes and specific excitation and emission programs. Most SR technologies heavily rely on image computation and processing to retrieve SR information. However, factors such as fluorescence group photophysics, chemical environment of the sample, and optical settings may cause ...

    2024-01-23
    Посмотреть перевод
  • Chip guided beam for new portable 3D printers

    Imagine being able to carry a 3D printer with you and quickly create low-cost objects, such as fastening bicycle wheels or parts needed for critical medical surgeries. Scientists from the Massachusetts Institute of Technology (MIT) and the University of Texas at Austin have combined silicon photonics and photochemical technology to successfully develop the first chip based 3D printer, taking a cru...

    2024-06-18
    Посмотреть перевод
  • Aerotech's next-generation laser processing technology for medical device manufacturing

    Recently, Aerotech Inc., a global leader in precision motion control and automation, launched the ultimate cylindrical laser machining motion platform LaserTurn160. LaserTurn160 is designed for unparalleled precision and efficiency, with a 40% increase in production capacity compared to similar systems, setting a new standard for medical device manufacturing. Extremely high efficiency, unparalle...

    02-08
    Посмотреть перевод
  • Creativity Falcon 2 laser cutting machine will be launched in Germany equipped with a new 60W laser head

    Starting from June 20th, The Creativity Falcon 2 laser cutting machine will also be launched in Germany, equipped with a new 60W laser head. With this ability, fully encapsulated equipment can now also be carved into steel. High power is achieved through twelve 5-watt laser diodes, whose beams are combined with each other. This will make it possible to cut 22mm thick lime wood and 30mm thick or...

    2024-05-29
    Посмотреть перевод
  • Researchers have successfully developed the world's first superconducting broadband photon detector

    Researchers at the National Institute of Information and Communication Technology in the United States have invented a new structure of a superconducting strip photon detector that can achieve efficient photon detection even in wide strips, and have successfully developed the world's first superconducting wide strip photon detector.The band width of the detector is more than 200 times that of trad...

    2023-11-02
    Посмотреть перевод