Русский

Xi'an Institute of Optics and Fine Mechanics: New progress in large field two-photon scattering microscopy imaging technology

608
2025-04-15 14:47:18
Посмотреть перевод

Adaptive optics is a technique that improves imaging quality by correcting wavefront distortion. Interference focus sensing (IFS), as a new method proposed in the field of adaptive optics in recent years, has been proven to have significant effects in correcting complex aberrations in deep tissue imaging. This technology is based on measuring a single location within the sample to determine the calibration mode. This article proposes an image-based interferometric focal sensing method (IBIFS), which uses conjugate adaptive optics configuration and feedback information from image quality indicators to progressively estimate and correct the wavefront throughout the entire field of view. The sample conjugate configuration achieves synchronous correction of multiple points within the entire field of view by measuring each position point by point and correcting the mode. We conducted experimental verification of the method using fluorescent microspheres and mouse brain slices as samples on our independently built two-photon microscope system. The results indicate that compared with methods based on regions of interest, this method not only has a larger effective field of view, but also achieves more stable optimization effects.

Recently, the research team led by Dr. Yao Baoli from the National Key Laboratory of Ultrafast Optics Science and Technology at the Xi'an Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, made progress in the field of large field two-photon scattering microscopy imaging. The related research results were published in Nanophotonics.

The most common AO method in the field of two-photon microscopy imaging is the Zernike mode decomposition method, which has a good effect on compensating for weaker aberrations. However, due to the limitations of the optical memory effect range, phase correction is only effective for a small field of view.

In response to the above issues, the research team proposed a large field wavefront correction method for deep tissue microscopy imaging - image-based interferometric focal sensing wavefront correction method (Figure 1). This method utilizes full field image information evaluation parameters as inputs for the interferometric focus induction method, achieving more stable correction effects while exhibiting high stability and anti-interference characteristics.

 



Figure 1. Schematic diagram of image-based interferometric focus sensing (IBIFS) method


In the resonance scanning galvanometer two-photon excitation fluorescence microscopy imaging system, researchers first performed large field wavefront correction on the fluorescent ball sample under the scatterer (Figure 2). The experimental results showed that the ROI based method only had good correction effect on the field of view near the reference point B1, while the IBIFS method (MHF based) can adjust the correction phase by using the image information feedback of the entire field of view, which has the correction effect of the entire field of view.


Figure 2. Scattering correction experiment results of fluorescent ball samples


In the scattering correction experiment of mouse brain nerve slice samples, the experimental results (Figure 3) showed that the ROI based correction effect depends on the sample structure distribution in the reference area, with better local optimization effect and poorer global optimization effect. The total intensity enhancement factor of the image corrected by the IBIFS method is 37% higher than that based on small area signals, achieving more stable large field of view correction. This technology can be applied to high-speed resonance scanning two-photon microscopy, providing enhanced microscopy imaging tools for fields such as neuroscience and developmental biology.

 



Figure 3. Scattering correction experiment results of mouse brain slice samples


The research is supported by the National Natural Science Foundation of China's National Major Scientific Instrument Development Project, National Key R&D Program, and Shaanxi Province's Key Industrial Chain Project.
The first author of the paper is Yang Ruiwen, a doctoral student from Xi'an Institute of Optics and Fine Mechanics in 2021. The corresponding authors are Researcher Yao Baoli and Senior Experimenter Yang Yanlong. Xi'an Institute of Optics and Fine Mechanics is the first completion unit and the corresponding unit.

Source: opticsky

Связанные рекомендации
  • Laser gyroscopes measure small changes in daytime length on Earth

    Recently, scientists used laser gyroscopes to measure that the change in Earth's rotational speed is less than one millionth. This technology can help scientists understand the complex flow of water and air, which can cause the smallest adjustments to the Earth's rotation.The Earth's rotation is not completely stable. Planets accelerate or slow down as they rotate, slightly shortening or prolongin...

    2023-09-19
    Посмотреть перевод
  • Tower Semiconductor is preparing to add laser integrated PIC for Scintil

    Grenoble stated that in the context of growing demand driven by artificial intelligence and 5G, "key" milestones have strengthened its supply chain.Scantil Photonics, a subsidiary of CEA Leti that focuses on silicon photonics, has stated that its integrated laser design is now being produced by Tower Semiconductor, a wafer foundry partner.This method describes this development as a "crucial step f...

    2024-02-29
    Посмотреть перевод
  • LM GROUP USA expands its North American office

    Recently, BLM GROUP USA, a leading manufacturer of laser tube and sheet metal processing equipment, announced that its North American headquarters in Novi, Michigan has officially started construction, with plans to add 65000 square feet of modern facilities. It is expected to be completed and put into use in the third quarter of 2025.The specific investment amount for this expansion has not been ...

    2024-08-03
    Посмотреть перевод
  • TRUMPF utilizes a laser driven X-ray source to improve electric vehicle batteries

    In the future, electric vehicle battery manufacturers can further improve the durability and performance of electric vehicle batteries through compact X-ray sources. The XProLas development partnership has now begun to develop these laser driven X-ray sources under the leadership of TRUMPF. The first batch of demonstration systems will be completed in 2026. In the future, manufacturers will be abl...

    2024-03-01
    Посмотреть перевод
  • Researchers have demonstrated a breakthrough boson sampling method using ultracold atoms in optical lattices

    JILA researcher, National Institute of Standards and Technology (NIST) physicist, physics professor Adam Kaufman and his team at the University of Colorado Boulder, as well as NIST collaborators, demonstrated a new method of cross laser beam lattice sampling using ultracold atoms for boson sampling in two-dimensional optics. This study, recently published in the journal Nature, marks a significant...

    2024-05-10
    Посмотреть перевод