日本語

Nanchang University research progresses in acoustic resolution photoacoustic microimaging enhancement

752
2024-09-18 11:30:16
翻訳を見る

As a promising imaging modality that combines the high spatial resolution of optical imaging and the deep tissue penetration ability of ultrasound imaging, photoacoustic microscopy (PAM) has attracted a lot of attention in the field of biomedical research, and has a wide range of applications in many fields, such as tumor detection, dermatology, and vascular morphology assessment. Depending on the imaging modality, PAM can be categorized into optical resolution photoacoustic microscopy (OR-PAM) and acoustic resolution photoacoustic microscopy (AR-PAM.) OR-PAM utilizes optically strong focusing to achieve high lateral resolution (<5 μm) imaging. However, light scattering within biological tissues limits the penetration depth of OR-PAM (no more than 1-2 mm). In contrast, AR-PAM exhibited deeper imaging (~3-10 mm). However, this enhanced effect is accompanied by a decrease in lateral resolution (>50 μm) and an increase in background noise. How to realize AR-PAM imaging with high lateral resolution without sacrificing imaging depth has been a pressing problem for PAM.

Recently, a research team from the Laboratory of Imaging and Visual Representation, Nanchang University, proposed an acoustic-resolution photoacoustic microscopy enhancement strategy based on the mean-reverting diffusion model to realize the transition from acoustic resolution to optical resolution. The result is published as “Mean-reverting diffusion model-enhanced acoustic-resolution photoacoustic microscopy for resolution enhancement: toward The results were published in the Journal of Innovative Optical Health Sciences, a leading journal in the field of biomedical photonics, under the title of “optical resolution”.

Main research content

The research team proposes a mean-regression diffusion model-based enhancement strategy for acoustic-resolution photoacoustic microscopy to achieve enhancement from acoustic to optical resolution. In the training stage, a mean-reversion diffusion model is trained to learn a priori information about the data distribution by modeling the quality reduction process from high-resolution PAM images to low-resolution AR-PAM images with fixed Gaussian noise. In the reconstruction stage, the learned a priori information is used to iteratively sample the noise states to generate a high resolution image from the low quality AR-PAM image. 

 


Figure 1.Flowchart of AR-PAM enhancement algorithm based on mean-reversion diffusion modeling


As a validation, the research team evaluated the performance of the proposed method using in vivo mouse experimental data. In a scene with a lateral resolution of 55 μm and a signal-to-noise ratio (SNR) of 35 dB, the method was compared with the conventional RL deconvolution method, the CycleGAN method, and the FDUnet method, and the results are shown in Figure 2. The enhancement results of the proposed method show higher quality and superior lateral resolution. The Peak Signal to Noise Ratio (PSNR) and Structural Similarity (SSIM) reached 31.96 dB, 0.91, respectively, which is 136% and 54% improvement over the RL deconvolution method. 

 



Fig. 2. Comparison of the reconstruction results of different methods.


In addition, in order to further validate the enhancement performance of the model on large-scale images, the research team also used complete live mouse cerebrovascular images for experiments. It can be seen that the enhanced image (as shown in Fig. 3(c)) has a clearer vascular topology, higher lateral resolution, and stronger image contrast. It is noteworthy that the continuity of the vessels at the sub-image joints is well maintained without obvious artifacts. Compared with the true-value image (as shown in Fig. 3(a)), the PSNR and SSIM of the AR-PAM image (as shown in Fig. 3(b)) were 19.39 dB and 0.53, respectively, and those of the model-enhanced image were improved to 24.72 dB and 0.73, respectively, which were 27% and 38% higher compared to the AR-PAM, respectively. The results show that the proposed method can still significantly improve the lateral resolution of large-size AR-PAM images. 

 



Fig.3. Resolution enhancement results for large size AR-PAM images.



Conclusion and Outlook

This study proposes a new AR-PAM enhancement strategy based on a mean-reversion diffusion model to achieve a balance between AR-PAM and OR-PAM imaging depth and lateral resolution. The method models the quality reduction process from OR-PAM to low quality AR-PAM images. Subsequently, a numerical method is used to iteratively perform an inverse-time SDE aimed at reconstructing high-quality images from a homogenized state. The method significantly improves the lateral resolution of AR-PAM without sacrificing the imaging depth, which has the potential to improve the quality of PAM imaging and extend its application range.

Source: opticsky

関連のおすすめ
  • Researchers have created the first organic semiconductor laser to operate without the need for a separate light source

    OLED is located at the top and is formed by an organic layer between the contacts. Apply voltage to it, inject charge and generate light, which in turn excites organic laser. Organic lasers contain a grating that can generate feedback and diffract some of the laser out of the structure.Organic laserResearchers have created the first organic semiconductor laser to operate without the need for a sep...

    2023-11-29
    翻訳を見る
  • Researchers have created the first organic semiconductor laser that can be operated without the need for a separate light source

    Researchers at the University of St. Andrews in Scotland have manufactured the first organic semiconductor laser to operate without the need for a separate light source - which has proven to be extremely challenging. The new all electric driven laser is more compact than previous devices and operates in the visible light region of the electromagnetic spectrum. Therefore, its developers stated that...

    2023-11-15
    翻訳を見る
  • Alliance unit Radiant High Tech Blue Purple Laser Assists in Ocean Exploration

    The ocean covers over 71% of the Earth's surface, and so far humans have only explored about 5% of the ocean. This means that there are still 95% of the depths of the ocean that we know nothing about, making it the most mysterious and unknown place on our planet.600 years ago, Zheng He led a fleet to play the prelude to the era of great navigation, laying the foundation for us to understand the wo...

    2023-11-06
    翻訳を見る
  • Diamond Light Source and NPL reach a new five-year agreement

    Recently, two leading UK scientific institutions, Diamond Light Source and National Physical Laboratory (NPL), have reached a new five-year agreement to promote joint collaborative efforts.The agreement was approved by signing a Memorandum of Understanding (MoU), which will bring these two institutions together.Diamond Light Source is a national synchrotron facility in the UK known for generating ...

    2024-04-25
    翻訳を見る
  • Alcon acquires ophthalmic laser equipment company for $466 million

    On July 3rd local time, Swiss ophthalmic care giant Alcon announced the acquisition of Israeli medical technology company Belkin Vision and its laser equipment assets for treating glaucoma.The transaction includes a prepayment of $81 million, of which approximately $65 million is in cash. In addition, if Alcon can establish this technology as the preferred first-line treatment option for clinical ...

    2024-07-09
    翻訳を見る