Italiano

Automated methods for background estimation in laser spectroscopy

388
2023-11-24 14:35:28
Vedi traduzione

A new automated method for spectral background estimation in laser spectroscopy ensures the accuracy of quantitative analysis with minimal human intervention.

When using laser-induced breakdown spectroscopy in spectral analysis, scientists may encounter various obstacles. The most common challenge faced by scientists when conducting elemental analysis is to optimize the interaction between the laser and the sample, pay attention to changes in laser energy, and the convergence of environmental noise, which helps to create different backgrounds in the collected spectra. All these obstacles will have a significant impact on the analysis.

In a recent study published in the Journal of Spectroscopy Part B: Atomic Spectroscopy, a research group from Jiangnan University introduced a new LIBS method aimed at automatically estimating and removing different spectral backgrounds. Under the leadership of Chen Hao from the School of Mechanical Engineering at Jiangnan University, researchers proposed a method that utilizes window functions, differential concepts, and piecewise cubic Hermite interpolation polynomials.

In this experiment, Chen and his team conducted a series of simulation experiments to evaluate background correction methods. They found that their proposed method performs better than existing techniques such as asymmetric least squares and modelless background correction. By utilizing window functions, Pchip, and differential concepts, the new method improves the ability to eliminate white noise and baseline distortion, achieving a better signal-to-noise ratio than previous methods.

The research team also found that their method improved the processing of background baseline jumps.
The researchers applied their method to seven different aluminum alloys and observed a correlation between spectral intensity and magnesium concentration.

It is worth noting that in the experiment of measuring magnesium concentration in aluminum alloys, the correlation coefficient between predicted concentration and actual concentration significantly improved after correction.

The coefficients for ALS and model free methods are 0.9913 and 0.9926, respectively, while the coefficients for this new method have decreased from the initial 0.9943 to 0.9154.

These findings not only validate the effectiveness of this automated method, but also pave the way for future research to improve the accuracy of LIBS spectral analysis.

Source: Laser Network

Raccomandazioni correlate
  • Investing nearly £ 520 million, this synchrotron light source in the UK will be upgraded

    Recently, the UK's national synchrotron "Diamond Light Source" announced an investment of nearly £ 520 million ($648.3 million) to implement three new flagship beam lines and upgrade existing beam lines. This comprehensive upgrade will be delivered by 2030.The Department for Science, Innovation, and Technology and the biomedical charity Wellcome jointly approved the facility upgrade project,...

    2023-09-27
    Vedi traduzione
  • Laser Wire Solutions and HumanTek Jointly Enter the Korean Laser Wire Stripping Market

    Recently, Laser Wire Solutions officially welcomed its important distribution partner in South Korea - HumanTek. This cooperation marks the official establishment of HumanTek as a branch of Laser Wire Solutions in Korea, and both parties will work together to provide excellent services for the Korean laser wire stripping market.HumanTek, with its deep foundation in the Korean market and strong pro...

    2024-07-03
    Vedi traduzione
  • A new type of flexible reflective mirror can improve the performance of X-ray microscopy

    A research team in Japan has designed a flexible and shapable X-ray reflector, achieving significant accuracy and higher stability at the atomic level.This new technology, developed by Satoshi Matsuyama and Takato Inoue from the Graduate School of Engineering at Nagoya University, in collaboration with the Japanese Institute of Physical and Chemical Research and JTEC Corporation, improves the perf...

    2024-05-06
    Vedi traduzione
  • Innoviz Technologies, a publicly listed laser radar company, has laid off approximately 9% of its workforce

    On February 5, 2025, Innoviz Technologies, an Israeli laser radar listed company, announced operational optimization measures to extend the duration of the company's cash reserve usage and accelerate profitability and free cash flow generation. To maximize efficiency, the company will reduce investment in developing mature areas. These measures will result in a reduction of approximately 9% in the...

    02-07
    Vedi traduzione
  • Making Infrared Light Visible: New Equipment Utilizes 2D Materials to Convert Infrared Light

    Infrared imaging and sensing technology can be used in various fields, from astronomy to chemistry. For example, when infrared light passes through a gas, sensing changes in light can help scientists identify specific properties of the gas. The use of visible light may not always achieve this sensing.However, existing infrared sensors are bulky and inefficient. In addition, due to the use of infra...

    2024-06-24
    Vedi traduzione